Specifications
Gemco 2110 Shut Height Monitor
- Power Requirements — 85 - 265 VAC
50/60 Hz; Internally Fused at 1.5 Amps
- Temperature — Operating: 32° to
131° F; Storage: 0° to 150° F
- Environmental — Humidity: 5% to
95%; Non-condensing
- Shock & Vibration — Tested to: MILSTD
810E, Method 514.4, Category 10,
20 - 2K Hz, 2G sine, 0.04 G2/Hz random.
To UL 491, SA 19, 10 - 150 Hz,
10G sine.
- Electromagnetic Compatibility —
Tested to: IEC 801-2, Level 5
(Electrostatic discharge requirements);
IEC 801-4, Level 4 (Electrical fast transient/
burst requirements);IEC 801-5,
Level 3,5 (Surge immunity requirements)
- Memory Retention Time — Maintains
last programmed values for ten (10)
years without power
- Relay Contact Ratings — All relays
rated UL & CSA for 1⁄4 HP, 125 to 250
VAC; 8A 250 VAC, 30 VDC, Shock
Resistant to 10 G
- Movement Input — 85 - 265 VAC, 12
mA (rms) maximum; optical isolated to
3200 VDC/2250 VAC
- Program Mode Key Input — Dry
Contact; Open Collector (drain) ONLY;
+5 VDC maximum — Current 0.2 mA
- RS - 232 Output — 115.2 K baud
- RS - 485 Output — 115.2 K baud
Software Specifications:
- Four (4) Programming Keys
- Software-Controlled Upper and Lower Limits
- Programmable Bolster Offset
- Programmable Zero Offset
- Programmable Movement Detection
- Programmable Wire Speed (LDT Modules)
- Programmable Count Direction (LDT Modules)
- Programmable Scale Factor (Resolver
Module)
- Programmable Negative Overshoot
- Programmable Position “Hold”
- Read Out in Inches or Millimeters